中国地质学会岩矿测试技术专业委员会、国家地质实验测试中心主办

常压环境下铅笔芯的质谱放电行为研究

周亚飞, 李操, 肖赛金, 陈焕文, 张兴磊. 常压环境下铅笔芯的质谱放电行为研究[J]. 岩矿测试, 2013, 32(3): 409-414.
引用本文: 周亚飞, 李操, 肖赛金, 陈焕文, 张兴磊. 常压环境下铅笔芯的质谱放电行为研究[J]. 岩矿测试, 2013, 32(3): 409-414.
Ya-fei ZHOU, Cao LI, Sai-jin XIAO, Huan-wen CHEN, Xing-lei ZHANG. Study on Discharge Behavior of Pencil Lead at Ambient Pressure by Mass Spectrometry[J]. Rock and Mineral Analysis, 2013, 32(3): 409-414.
Citation: Ya-fei ZHOU, Cao LI, Sai-jin XIAO, Huan-wen CHEN, Xing-lei ZHANG. Study on Discharge Behavior of Pencil Lead at Ambient Pressure by Mass Spectrometry[J]. Rock and Mineral Analysis, 2013, 32(3): 409-414.

常压环境下铅笔芯的质谱放电行为研究

  • 基金项目:
    国家自然科学基金项目(21265001);江西省自然科学基金项目(2010GZH0002);江西省科技支撑计划项目(20113BCB24024)
详细信息
    作者简介: 周亚飞,硕士研究生,分析化学专业。E-mail: zhouyafei01234@163.com
    通讯作者: 张兴磊,讲师,主要从事分析化学研究。E-mail: leizi8586@126.com
  • 中图分类号: P619.252;O657.63

Study on Discharge Behavior of Pencil Lead at Ambient Pressure by Mass Spectrometry

More Information
  • 铅笔芯内所含石墨和黏土的混合比例如果不符合国家标准,将不利于计算机读卡设备正确识读和非专业人士鉴定。本文采用常压质谱法对不同黑度(石墨含量)、硬度的铅笔芯进行分析,为实现铅笔品质的快速鉴别提供了一种有效的技术手段。该方法直接将铅笔芯作为电离装置,在高电压作用下以空气(相对湿度40%)为介质,铅笔芯产生电晕放电,其放电行为能够对质谱信号产生直接影响。实验优化了工作条件,分析了6种型号铅笔芯(4B、3B、2B、HB、H和2H)中石墨含量与其质谱信号之间的关系,并结合主成分分析(PCA)对不同型号铅笔芯进行区分。结果表明,不同型号铅笔芯的放电行为对质谱信号产生较大影响,质谱信号随铅笔芯中石墨含量的增多而增强;6种型号铅笔芯区分正确率高达99%以上。此方法操作简单且可重复性强,可用于市场上不同品质铅笔芯的快速鉴定。
  • 加载中
  • 图 1  影响总离子流信号强度的4个实验条件的优化

    Figure 1. 

    图 2  不同型号铅笔芯对总离子流强度的影响

    Figure 2. 

    图 3  铅笔芯在正离子检测模式下的质谱图

    Figure 3. 

    图 4  正离子检测模式下铅笔芯质谱数据PCA分析结果

    Figure 4. 

  • [1]

    Burgelman J C. Henry P. The Pencil—A History of Design and Circumstance [M].Revue belge de philologie et d'histoire, 1994, 72(4): 929-930.

    [2]

    Black C, Poile C, Langley J, Herniman J. The use of pencil lead as a matrix and calibrant for matrix-assisted laser desorption/ionisation [J].Rapid Communications in Mass Spectrometry, 2006, 20(7): 1053-1060. doi: 10.1002/(ISSN)1097-0231

    [3]

    Langley G J, Herniman J M, Townell M S. 2B or not 2B, that is the question: Further investigations into the use of pencil as a matrix for matrix-assisted laser desorption/ionisation [J].Rapid Communications in Mass Spectrometry, 2006, 21(2): 180-190.

    [4]

    陈焕文,赖劲虎,周瑜芬,郇延富,李建强,张燮,王志畅,罗明标.表面解吸常压化学电离源的研制及应用[J].分析化学, 2007,35(8): 1233-1240. http://www.cnki.com.cn/Article/CJFDTOTAL-FXHX200708035.htm

    [5]

    陈焕文,赖劲虎,周瑜芬,郇延富,李建强,张燮,王志畅,罗明标.表面解吸常压化学电离源的研制及应用[J].分析化学, 2007,35(8): 1233-1240. http://www.cnki.com.cn/Article/CJFDTOTAL-KXTB201220011.htm

    [6]

    贾滨,张兴磊,丁健桦,杨水平,陈焕文.电喷雾萃取电离质谱技术及其应用进展[J].科学通报,2012,57(20): 1918-1927. http://www.cnki.com.cn/Article/CJFDTOTAL-YKCS201201011.htm

    [7]

    欧阳永中,韩京,鲍廷义,贾滨,李超,汪志成.新型常压热解离化学电离装置的研制及应用[J].岩矿测试, 2012,31(1): 64-70. doi: 10.1002/(ISSN)1097-0231

    [8]

    Chen H W, Pan Z Z, Talaty N, Raftery D, Cooks R G. Combining desorption electrospray ionization mass spectrometry and nuclear magnetic resonance for differential metabolomics without sample preparation [J].Rapid Communications in Mass Spectrometry, 2006, 20(10): 1577-1584. doi: 10.1016/S1872-2040(07)60079-6

    [9]

    Chen H W, Lai J H, Zhou Y F, Huan Y F, Li J Q, Xie Z, Wang Z C, Luo M B. Instrumentation and character-ization of surface desorption atmospheric pressure chemical ionization mass spectrometry [J].Chinese Journal of Analytical Chemistry, 2007, 35(8): 1233-1240. doi: 10.1021/ac900063u

    [10]

    Yang S, Ding J, Zheng J, Hu B, Li J, Chen H, Zhou Z, Qiao X. Detection of melamine in milk products by surface desorption atmospheric pressure chemical ionization mass spectrometry [J].Analytical Chemistry, 2009, 81(7): 2426-2436. doi: 10.1021/ac9013594

    [11]

    Ding J, Gu H, Yang S, Li M, Li J, Chen H. Selective detection of diethylene glycol in toothpaste products using neutral desorption reactive extractive electrospray ionization tandem mass spectrometry [J].Analytical Chemistry, 2009, 81(20): 8632-8638. doi: 10.1021/jf9018504

    [12]

    Pan Z Z, Gu H W, Talaty N, Chen H W, Shanaiah N, Hainline B E, Cooks R G, Raftery D. Principal component analysis of urine metabolites detected by NMR and DESI-MS in patients with inborn errors of metabolism [J].Analytical and Bioanalytical Chemistry, 2007, 387(2): 539-549. doi: 10.1007/s00216-006-0546-7

    [13]

    Wu Z C, Chen H W, Wang W L, Jia B, Yang T L, Zhao Z F, Ding J H, Xiao X X. Differentiation of dried sea cucumber products from different geographical areas by surface desorption atmospheric pressure chemical ionization mass spectrometry [J].Journal of Agricultural and Food Chemistry, 2009, 57(20): 9356-9364. doi: 10.1021/jf0720234

    [14]

    Pan Z Z, Gu H W, Talaty N, Chen H W, Shanaiah N, Hainline B E, Cooks R G, Raftery D. Principal component analysis of urine metabolites detected by NMR and DESI-MS in patients with inborn errors of metabolism [J].Analytical and Bioanalytical Chemistry, 2007, 387(2): 539-549. doi: 10.1002/pmic.200701121

    [15]

    Chen H W, Liang H Z, Ding J H, Lai J H, Huan Y F, Qiao X L.Rapid differentiation of tea products by surface desorption atmospheric pressure chemical ionization mass spectrometry [J].Journal of Agricultural and Food Chemistry, 2007, 55(25): 10093-10100. doi: 10.1021/tx7004212

    [16]

    Yao I, Sugiura Y, Matsumoto M, Setou M. In situ proteomics with imaging mass spectrometry and principal component analysis in the Scrapper-knockout mouse brain [J].Proteomics, 2008, 8(18): 3692-3701. doi: 10.1039/b924156f

    [17]

    Kellert M, Wagner S, Lutz U, Lutz W K. Biomarkers of furan exposure by metabolic profiling of rat urine with liquid chromatography-tandem mass spectrometry and principal component analysis [J].Chemical Research in Toxicology, 2008, 21(3): 761-768. doi: 10.1007/s10800-008-9518-2

    [18]

    Law W S, Chen H W, Balabin R, Berchtold C, Meier L, Zenobi R. Rapid fingerprinting and classification of extra virgin olive oil by microjet sampling and extractive electrospray ionization mass spectrometry [J].Analyst, 2010, 135(4): 773-778. doi: 10.1002/wics.v2:4

  • 加载中

(4)

计量
  • 文章访问数:  569
  • PDF下载数:  1
  • 施引文献:  0
出版历程
收稿日期:  2012-10-25
录用日期:  2012-12-25

目录